KBT-D系(xi)列直流電源(yuan)防(fang)雷(lei)模塊為分體式(shi)結構(gou),可插拔,帶劣化指示窗口。用于直流電源(yuan)第三級防(fang)護,標準35mm導軌安裝。采用并聯安裝方式(shi),不影(ying)響電源(yuan)線路的正常工作。
產品介紹
技術參數
名(ming)稱(cheng) |
直流電源防(fang)雷模(mo)塊 |
直流電源防雷模塊(kuai) |
||||||||
產(chan)品編碼 |
D09-01 |
D09-02 |
D09-03 |
D09-04 |
D09-05 |
D09-06 |
D09-07 |
D09-08 |
D09-09 |
D09-10 |
型號(hao) |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
KBT-D |
規格 |
220/2/10 |
110/2/10 |
48/2/10 |
24/2/10 |
12/2/10 |
220/2/20 |
110/2/20 |
48/2/20 |
24/2/20 |
12/2/20 |
防雷保護等級(ji) |
第(di)三級 |
第(di)三級(ji) |
||||||||
試(shi)驗(yan)類別 |
T2(Ⅱ級) |
T2(Ⅱ級) |
||||||||
額定(ding)工作電(dian)壓Un(V) |
DC220 |
DC110 |
DC48 |
DC24 |
DC12 |
DC220 |
DC110 |
DC48 |
DC24 |
DC12 |
最大持續工(gong)作電(dian)壓Uc(V) |
DC350 |
DC180 |
DC85 |
DC38 |
DC22 |
DC350 |
DC180 |
DC85 |
DC38 |
DC22 |
標稱放電電流In(kA) |
10 |
10 |
10 |
10 |
10 |
20 |
20 |
20 |
20 |
20 |
最大(da)放電(dian)電(dian)流Imax(kA) |
20 |
20 |
20 |
20 |
20 |
40 |
40 |
40 |
40 |
40 |
電壓保護水(shui)平Up(V) |
710 |
360 |
165 |
93 |
53 |
800 |
400 |
200 |
140 |
80 |
連接導線標準(mm2) |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
≥2.5 |
接地線標準(zhun)(mm2) |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
≥4 |
推薦串(chuan)聯過流保護器 |
20A |
20A |
20A |
20A |
20A |
32A |
32A |
32A |
32A |
32A |
外形(xing)尺寸(cun)(mm) |
36×66×90 |
|||||||||
組合方式(shi)及結構形式(shi) |
2P/插拔(ba)式 |
|||||||||
接口類型 |
M5螺絲壓接 |
|||||||||
保護模式 |
+/- -PE |
|||||||||
響應時間t(ns) |
<25 |
|||||||||
外(wai)殼(ke)材料 |
PBT阻燃塑(su)料 |
|||||||||
外殼阻(zu)燃(ran)等級 |
UL94-V0 |
|||||||||
外(wai)殼防護等級 |
IP20 |
|||||||||
安(an)裝方式 |
35mm電氣(qi)導(dao)軌 |
|||||||||
遙(yao)信(xin)告(gao)警裝置 |
常開/常閉(bi)(可選配(pei)置) |
|||||||||
劣化(hua)指示 |
脫離(li)器(qi)動作后(hou)正面視窗指示(shi)紅色 |
|||||||||
工作溫度(du)(℃) |
-40~+85 |
|||||||||
參考標準 |
IEC61643-1:2005 GB18802.1-2011 |
應用范圍
適用于通信系(xi)統(tong)、監控系(xi)統(tong)和工(gong)業自動(dong)化系(xi)統(tong)的(de)直流電(dian)源(yuan)的(de)過(guo)電(dian)壓(ya)保護。